Sets of light filters

Sets of light filters

Sets of light filters differ in structure and the quantity of the normalized parameters. They are intended for carrying out primary periodic checkings of devices

Overall dimensions of the light filter in a frame are 12,5х12,5х45 mm

The sizes of light zone are 7х10 mm

Checking of devices:

  • Analyzer of platelets aggregation AP2110
  • Turbudimetric clotter CGL2110
  • Four-channel clotter CT2410

Characteristics

The set has 6 light filters with various coefficients of spectral transmission and is certified for transmission waves length of 472 and 600 nanometers

Checking of devices:

  • Spectrophotometers of series PV1251
  • PM2111 photometer
  • Automated photometer PA2600

Description

The set has 8 light filters, including 6 with various coefficients of spectral transmission, certified for optical density under waves lengths of 340, 405, 520, 540, 570, 620, 670, 850 nanometers. One light filter is intended for check installation correctness under waves lengths and certified for several maxima of absorption zones in the range from 35 to 880 nanometers at the allocated spectral interval of 5 nanometers. The eighth light filter is used for check level of the disturbing radiation

Checking of devices:

  • Densitometer DM2120

Characteristics

The set has 6 light filters with various coefficients of spectral transmission and it is certified for optical density under the following lengths of waves: 472, 592 and 605 nanometers. The special holder is used for installation of light filters to the device

Checking of devices:

  • Analyzer of platelets aggregation AP2110
  • Clotter CGL2110 turbidimetric
  • Four-channel clotter CT2410
  • Spectrophotometer PV1251 series
  • UV PB2201 spectrophotometer
  • PM2111 photometer
  • Automated photometer PA2600
  • Spectrofluorimeter CM2203

Characteristics

The set has 8 light filters, including 6 with various coefficients of spectral transmission (2, 8, 13, 32, 66 and 92% T on the wavelength of 500 nanometers), 250, 340, 405, 520, 540, 570, 620, 670, 850 and 960 nanometers certified for optical density under lengths of waves also under transmission of wave lengths of 472 and 600 nanometers. One light filter is intended for installation correctness check under lengths of waves and certified for several maxima of absorption zone in the range from 350 to 880 nanometers at the allocated spectral interval of 1 and 5 nanometers. The eighth light filter is used for check of level of the disturbing radiation