Turbidimetric clotter (single-channel) CGL2110

Turbidimetric clotter (single-channel)

CGL2110 model

Turbidimetric clotter (single-channel) CGL2110 is intended for detection violations of fibrillation system in medical laboratories

  • Easy-to-work
  • Works with reagents of different producers
  • Built-in timer of sample incubation
  • Automatic switching on

Cell section

Thermostatically controlled (37 °C) cell section with electronic magnetic agitator

It is easy-to-work

The system of hints on the built-in clotter's LCD screen during operation

Open system

Clotter "SOLAR" operates with reagents of different producers at the user's choice

Connection of the printer

Possibility connection to the printer. Printing of research results

Built-in timer

Built-in timer of sample incubation

Automatic switching on

Automatic switching on time counting at the time of reagent adding, and auto switch off at the time of the beginning fibrin polymerization. Electronic pipettes synchronized with clotter are not required

In addition

Possibility of determination fibrinogen concentration in plasma with clotting time
State registry SI of RB No. 03 25 0481 97
State registry SI of the Russian Federation No. 16412-97
State registry SI UKE of UA-MI/3p-217-2000
Defined parameters
  • Clotting time
  • Trombine time
  • PTT
  • Concentration of fibrinogen
  • Factors of fibrillation II, V, VII, VIII, IX, X, XI, XII
  • Coagulability inhibitor: anti-thrombin III

Delivery set

  • Clotter CGL2110 turbidimetric
  • Polystyrine one-use cells - 3000 pieces
  • Anchors magnetic one-use - 3000 pieces
  • Pippetor 100 mcl - 1 piece
  • Pippetor 200 mcl - 1 piece
  • Tips for pippetors - 1000 pieces
By the additional order
  • Device for samples preparation PT2110G
  • Printer
  • Polystyrine one-use cells
  • Magnetic one-use anchors
General pronciplesturbidimetric
Diagram of measurementsingle-channel
Light source
light-emitting diode
Detectorsilicon photo diode
Plasma volume for one research0,1 ml
Termostatiing temperature(37 ±0,5) С
Indicatormultipurpose, liquid crystal
Dimensions335x235x125 mm
Weight4,0 kg
Energy consumption230 (± 10%) V, 50 Hz, 40 VA
Cell type

Optical wave length, mm

Internal dimensions, mm

Packing, pc
  20021

Polystyrene round cells

Ø8х45200
  20022

Magnetic one use anchors

Ø1,8х45200
Block of samples preparation PT2110G
For preparation of samples by thermal stabilization
Nominal temperature of termostating 37C ° more
Sets of the light filters KCC-003
For checking of the device
Overall dimensions of the light filter in the frame is 12,5х12,5х45 mm more