Turbidimetric clotter (single-channel)
CGL2110 model
Turbidimetric clotter (single-channel) CGL2110 is intended for detection violations of fibrillation system in medical laboratories
- Easy-to-work
- Works with reagents of different producers
- Built-in timer of sample incubation
- Automatic switching on
Cell section
Thermostatically controlled (37 °C) cell section with electronic magnetic agitatorIt is easy-to-work
The system of hints on the built-in clotter's LCD screen during operationOpen system
Clotter "SOLAR" operates with reagents of different producers at the user's choiceConnection of the printer
Possibility connection to the printer. Printing of research resultsBuilt-in timer
Built-in timer of sample incubationAutomatic switching on
Automatic switching on time counting at the time of reagent adding, and auto switch off at the time of the beginning fibrin polymerization. Electronic pipettes synchronized with clotter are not requiredIn addition
Possibility of determination fibrinogen concentration in plasma with clotting time


- Clotting time
- Trombine time
- PTT
- Concentration of fibrinogen
- Factors of fibrillation II, V, VII, VIII, IX, X, XI, XII
- Coagulability inhibitor: anti-thrombin III
Delivery set
- Clotter CGL2110 turbidimetric
- Polystyrine one-use cells - 3000 pieces
- Anchors magnetic one-use - 3000 pieces
- Pippetor 100 mcl - 1 piece
- Pippetor 200 mcl - 1 piece
- Tips for pippetors - 1000 pieces
By the additional order
- Device for samples preparation PT2110G
- Printer
- Polystyrine one-use cells
- Magnetic one-use anchors
General pronciples | turbidimetric |
Diagram of measurement | single-channel |
Light source | light-emitting diode |
Detector | silicon photo diode |
Plasma volume for one research | 0,1 ml |
Termostatiing temperature | (37 ±0,5) С |
Indicator | multipurpose, liquid crystal |
Dimensions | 335x235x125 mm |
Weight | 4,0 kg |
Energy consumption | 230 (± 10%) V, 50 Hz, 40 VA |
- № 20021
- № 20022
Cell type | Optical wave length, mm | Internal dimensions, mm | Packing, pc |
20021 | Polystyrene round cells | Ø8х45 | 200 |
20022 | Magnetic one use anchors | Ø1,8х45 | 200 |
Block of samples preparation PT2110G
For preparation of samples by thermal stabilization
Nominal temperature of termostating 37C ° more
For preparation of samples by thermal stabilization
Nominal temperature of termostating 37C ° more
Sets of the light filters KCC-003
For checking of the device
Overall dimensions of the light filter in the frame is 12,5х12,5х45 mm more
For checking of the device
Overall dimensions of the light filter in the frame is 12,5х12,5х45 mm more